Criticality of Gasketed Joint in a Hi-Hi Screw Plug Heat Exchanger
A gasketed joint in a Hi-Hi construction -with the tube-side pressure being higher than the shell-side pressure – is not critical as the net pressure is from the tube-side. This pressure works with the bolts, not against them, since, being